The Daily Insight

Connected.Informed.Engaged.

news

How to turn off trouble light on DCs power 832?

Written by David Osborn — 0 Views

How to turn off trouble light on DCs power 832?

If you will not be using the communicator functions, you have to turn them off by entering programming, turning off option 7 in section 015, and option 1 in section 380. Thanks for that. Just completed those steps but trouble light is still on.

How to troubleshoot DSC power series troubleshooting guide?

Put a 1K resistor (brown, black, red) across Bell+ and Bell- to verify the trouble condition clears. If the output is not being used make sure a 1K resistor (brown, black, red) is connected between O1 and AUX+.

How to reset a DSc alarm after the power has been off?

Reset DSC Alarm 1 Open the access door on the unit. 2 Press and hold the “RESET” key for 2 seconds. 3 Press the buttons “*72” if the alarm does not reset after pressing the RESET button. 4 Check the sensors if it still does not turn off. It means one of the sensors is detecting an alarm condition, such as a glass break or See More….

What does DSC stand for in DCS power?

DSC: Power series panels (632, 832, 864); trouble 3 (telephone line trouble) and/or trouble 4 (failure to communicate) shows on new/defaulted system. DSC panels default to the communicator turned on, and TLM (telephone line monitoring) turned on.

What does light mean on DSC power832 problem?

Light 4 = General System Tamper (Check Tamper on External Modules) Light 5 = General System Supervisory (Enter programming and enter 902) Light 6 = 5204 Power Supply Module Low Battery

If you will not be using the communicator functions, you have to turn them off by entering programming, turning off option 7 in section 015, and option 1 in section 380. Thanks for that. Just completed those steps but trouble light is still on.

When do I get the trouble light from a DSc panel?

I get the trouble light. Click to expand… When the trouble clears, the light will go out. What’s the problem? I have been using a DSC 832 panel in my house for a number of years now.

DSC: Power series panels (632, 832, 864); trouble 3 (telephone line trouble) and/or trouble 4 (failure to communicate) shows on new/defaulted system. DSC panels default to the communicator turned on, and TLM (telephone line monitoring) turned on.