The Daily Insight

Connected.Informed.Engaged.

general

How can I bypass a zone on my alarm system?

Written by Avery Gonzales — 0 Views

How can I bypass a zone on my alarm system?

To bypass a zone on your alarm system: Enter the following: Your 4-digit code The number 6 (bypass button) Two-digit zone number of the zone you want to bypass. (01, 02, 03, etc.) Repeat this process for all zones you would like to bypass.

How do I UN-bypass a bypassed zone on a Honeywell system?

Fire and Carbon Monoxide zones can not be bypassed on the Lynx Touch and Lyric panels. To clear the bypass, if the system is armed, perform a disarm command. This will un-bypass all bypassed zones. If the system is disarmed: select Security > Zones highlight the zones to be un-bypassed and select the “Clear Bypass” button at the bottom of the page.

How to recall the last set of bypass zones?

DSC Quick User Guide (PC1616/PC1832/PC1864) Page 2 DSC7 Recalling Bypassed Zones To recall the last set of bypassed zones: 1. Press *1, then your access code. 2. Press 9 9. 3. Press # to exit bypass mode and return to Ready state. 4. Continue with arming the system. Alarm Memory

How to bypass all faulted zones in Windows 10?

With the system in the disarmed state, from the Home screen select “Security.” Select the “Zones” icon. Selecting the “Bypass All Faulted” button allows you to bypass all faulted Burg zones, if “Force Bypass” is enabled in panel programming. The system displays a keypad.

Fire and Carbon Monoxide zones can not be bypassed on the Lynx Touch and Lyric panels. To clear the bypass, if the system is armed, perform a disarm command. This will un-bypass all bypassed zones. If the system is disarmed: select Security > Zones highlight the zones to be un-bypassed and select the “Clear Bypass” button at the bottom of the page.

What is bypassing a zone on a security system?

To bypass a zone on a Vista panel: The panel must be in the disarmed state, enter the 4 digit security code, followed by the number 6 [Bypass] and the 2 digit zone number to be bypassed (ex: [1234] [6] [04] to bypass zone 04 – always add a 0 in front of a single digit zone number). The keypad will display a bypass message for the zone number.

With the system in the disarmed state, from the Home screen select “Security.” Select the “Zones” icon. Selecting the “Bypass All Faulted” button allows you to bypass all faulted Burg zones, if “Force Bypass” is enabled in panel programming. The system displays a keypad.